Heidenhain Itnc 530 Error List |verified| May 2026
Error Messages
Abnormal Program Stops (900+):
These occur during execution when the control encounters a state it cannot resolve, such as a "950 NC-cancel error". Common Errors & Troubleshooting Error Code/Message Typical Cause Recommended Action Processor Check Error A (14) Insufficient memory for parameter files. Delete unneeded part programs to free space. Processor Check Error 0 (1/2) Incorrect CRC sum for control data. Contact your Heidenhain Service Agency . Input not in effect Illegal character entered (only 0-9, ., and - allowed). Check and re-enter valid characters. Kinematic model not switched Active program run or active "Tilt Working Plane" function.
MP Errors:
Errors like "153 MP: separator missing" or "154 MP: input value incorrect" indicate syntax or logic issues in the machine parameter list. heidenhain itnc 530 error list
- Write down the full error number and text.
- Press
ERRkey (if machine builder enabled) – shows additional info. - Check status display (soft keys:
PLC STATUS,SERVO TRACE). - Try to reset (press
CE/C+ machine manufacturer's reset button). - Check safety devices – doors, E-stops, limit switches.
- Reference axes – many errors clear after referencing.
Machine Parameter (MP) Errors
Processor check errors (1, 2, 3, 5) usually indicate memory/data corruption requiring service, while error 14 indicates full memory, solvable by deleting files. Error Messages Abnormal Program Stops (900+): These occur